Power and sample size calculation of comparative diagnostic accuracy studies with multiple correlated test results Journal Article


Authors: Liu, A.; Schisterman, E. F.; Mazumdar, M.; Hu, J.
Article Title: Power and sample size calculation of comparative diagnostic accuracy studies with multiple correlated test results
Abstract: We consider the power and sample size calculation of diagnostic studies with normally distributed multiple correlated test results. We derive test statistics and obtain power and sample size formulas. The methods are illustrated using an example of comparison of CT and PET scanner for detecting extra-hepatic disease for colorectal cancer. © 2005 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Keywords: comparative study; positron emission tomography; diagnostic procedure; computer assisted tomography; statistics; tomography, x-ray computed; colorectal neoplasms; models, statistical; colorectal tumor; positron-emission tomography; scintiscanning; radiography; statistical model; roc curve; biometry; diagnostic techniques and procedures; sample size; area under a curve; correlated measurements; power and sample size; receiver operating characteristic curves
Journal Title: Biometrical Journal
Volume: 47
Issue: 2
ISSN: 0323-3847
Publisher: Wiley V C H Verlag Gmbh  
Date Published: 2005-01-01
Start Page: 140
End Page: 150
Language: English
DOI: 10.1002/bimj.200410094
PUBMED: 16389911
PROVIDER: scopus
DOI/URL:
Notes: --- - "Cited By (since 1996): 3" - "Export Date: 24 October 2012" - "Source: Scopus"