Optimized planning for intraoperative planar permanent-seed implant Journal Article


Authors: Fung, A. Y.; Amols, H. I.; Zaider, M.
Article Title: Optimized planning for intraoperative planar permanent-seed implant
Abstract: We describe a fast, PC-based optimization planning system for a planar permanent-seed implant. Sites where this system is applicable include brain, lung, and head and neck. The system described here allows placing ribbons of different strengths and of different lengths along and across the implant plane. The program takes full advantage of the availability of different source strengths in inventory, and attempts to find configurations of ribbons that result in optimal dose uniformity over the prescription plane. Dosimetry is based on the AAPM TG 43 Report [R. Nath et al., Med. Phys. 22, 209-234 (1995)]. Compared with TG 43 parameters, the classical tables underestimate the I-125 source strengths needed by 40%. The use of several source strengths improves the plan. Typical optimization yields dose uniformity of 10%, and computing times are within 2-3 min. No further enhancement is obtained if ribbons are placed in a grid pattern as opposed to the (simpler) arrangement along parallel lines. Nor is it valuable to have variable ribbon lengths. For an I-125 implant the optimization system described here is a practical alternative to the (strictly speaking inapplicable) classical systems. It calculates correctly the total source strengths, and--most notably--generates plans with optimal dose uniformity. The fast computing time is well suited for planning during surgery in the operating room.
Keywords: comparative study; radiation dose; brain tumor; methodology; brain neoplasms; lung neoplasms; radiotherapy dosage; prostatic neoplasms; lung tumor; radioactive iodine; iodine radioisotopes; minimal residual disease; neoplasm, residual; head and neck neoplasms; intraoperative period; prostate tumor; radiotherapy planning, computer-assisted; radiotherapy, conformal; computer assisted radiotherapy; head and neck tumor; humans; human; male; article
Journal Title: Journal of Applied Clinical Medical Physics
Volume: 3
Issue: 3
ISSN: 1526-9914
Publisher: American College of Medical Physics  
Date Published: 2002-01-01
Start Page: 221
End Page: 226
Language: English
PUBMED: 12132944
PROVIDER: scopus
DOI: 10.1120/jacmp.v3i3.2566
PMCID: PMC5724596
DOI/URL:
Notes: Export Date: 14 November 2014 -- Source: Scopus
Altmetric
Citation Impact
BMJ Impact Analytics
MSK Authors
  1. Albert Fung
    20 Fung
  2. Howard I Amols
    157 Amols
  3. Marco Zaider
    171 Zaider