Evidence for shutter-speed variation in CR bolus-tracking studies of human pathology Journal Article


Authors: Yankeelov, T. E.; Rooney, W. D.; Huang, W.; Dyke, J. P.; Li, X.; Tudorica, A.; Lee, J. H.; Koutcher, J. A.; Springer, C. S. Jr
Article Title: Evidence for shutter-speed variation in CR bolus-tracking studies of human pathology
Abstract: The standard pharmacokinetic model for the analysis of MRI contrast reagent (CR) bolus-tracking (B-T) data assumes that the mean intracellular water molecule lifetime (τ i) is effectively zero. This assertion is inconsistent with a considerable body of physiological measurements. Furthermore, theory and simulation show the B-T time-course shape to be very sensitive to the τ i magnitude in the physiological range (hundreds of milliseconds to several seconds). Consequently, this standard model aspect can cause significant underestimations (factors of 2 or 3) of the two parameters usually determined: K trans, the vascular wall CR transfer rate constant, and v e, the CR distribution volume (the extracellular, extravascular space fraction). Analyses of animal model data confirmed two predicted behaviors indicative of this standard model inadequacy: (1) a specific temporal pattern for the mismatch between the best-fitted curve and data; and (2) an inverse dependence of the curve's K trans and v e magnitudes on the CR dose. These parameters should be CR, dose-independent. The most parsimonious analysis allowing for realistic τ i values is the 'shutter-speed' model. Its application to the experimental animal data essentially eliminated the two standard model signature inadequacies. This paper reports the first survey for the extent of this 'shutter-speed effect' in human data. Retrospective analyses are made of clinical data chosen from a range of pathology (the active multiple sclerosis lesion, the invasive ductal carcinoma breast tumor, and osteosarcoma in the leg) that provides a wide variation, particularly of K trans. The signature temporal mismatch of the standard model is observed in all cases, and is essentially eliminated by use of the shutter-speed model. Pixel-by-pixel maps show that parameter values from the shutter-speed analysis are increased by more than a factor of 3 for some lesion regions. This endows the lesions with very high contrast, and reveals heterogeneities that are often not seen in the standard model maps. Normal muscle regions in the leg allow validation of the shutter-speed model K trans, v e, and τ i magnitudes, by comparison with results of previous careful rat leg studies not possible for human subjects. Copyright © 2004 John Wiley & Sons, Ltd.
Keywords: osteosarcoma; adult; controlled study; middle aged; dose response; nonhuman; validation process; nuclear magnetic resonance imaging; magnetic resonance imaging; sensitivity and specificity; evidence-based medicine; reproducibility of results; models, biological; image interpretation, computer-assisted; animal experiment; animal model; pathology; breast neoplasms; retrospective study; algorithms; prediction; physiology; animalia; cancer invasion; experimental animal; imaging system; standardization; image enhancement; medical imaging; breast tumor; data analysis; contrast medium; contrast media; computer simulation; gadolinium pentetate; multiple sclerosis; medicine; gadodiamide; paget nipple disease; nuclear magnetic resonance; leg disease; sample size; velocity; muscle; lesions; cells; bolus-tracking; parsimony analysis; contrast; invasive ductal carcinoma; data reduction; contrast reagent; breast tumors; intraceullular water molecules; pharmacological parameters
Journal Title: NMR in Biomedicine
Volume: 18
Issue: 3
ISSN: 0952-3480
Publisher: John Wiley & Sons  
Date Published: 2005-05-01
Start Page: 173
End Page: 185
Language: English
DOI: 10.1002/nbm.938
PUBMED: 15578708
PROVIDER: scopus
DOI/URL:
Notes: --- - "Cited By (since 1996): 39" - "Export Date: 24 October 2012" - "CODEN: NMRBE" - "Source: Scopus"