Respiration artifacts in whole-body 18F-FDG PET/CT studies with combined PET/CT tomographs employing spiral CT technology with 1 to 16 detector rows Journal Article


Authors: Beyer, T.; Rosenbaum, S.; Veit, P.; Stattaus, J.; Müller, S. P.; DiFilippo, F. P.; Schoder, H.; Mawlawi, O.; Roberts, F.; Bockisch, A.; Kühl, H.
Article Title: Respiration artifacts in whole-body 18F-FDG PET/CT studies with combined PET/CT tomographs employing spiral CT technology with 1 to 16 detector rows
Abstract: Purpose: Co-registration accuracy in combined whole-body (WB) PET/CT imaging is impaired by respiration-induced mismatches between the CT and the PET. Furthermore, PET/CT misregistration may bias the PET tracer distribution following CT-based attenuation correction (CT-AC). With the introduction of multi-row CT technology of up to 16 detector rows into PET/CT designs, we investigated the incidence of respiration artifacts in WB PET/CT examinations of patients who were unable to follow any breath-hold instructions. Methods: A total of 80 WB studies from six international sites operating PET/CT tomographs with 1-, 2-, 4-, 6-, 8-, and 16-row spiral CT were included. PET/CT examinations were acquired with the patients breathing normally during both the CT and the PET scan, and CT-AC was performed routinely. All studies were anonymized and reviewed independently by three radiologists and three nuclear medicine specialists. We report the frequency and severity of artifacts on CT and PET for the thorax and the abdomen. Results: In WB PET/CT imaging of normally breathing patients, significant gains in diagnostic image quality can be expected from employing CT technology with six or more detector rows. In our study, fewer PET images appear distorted than corresponding CT images, which is due to the limited propagation of only mild CT image artifacts after the resampling of the CT-based attenuation map during CT-AC. Conclusion: In whole-body PET/CT imaging of normally breathing patients, respiration-induced artifacts are reduced in both magnitude and prominence for PET/CT systems employing CT components of six or more detector rows. © Springer-Verlag 2005.
Keywords: adolescent; adult; controlled study; aged; aged, 80 and over; middle aged; retrospective studies; major clinical study; positron emission tomography; diagnostic accuracy; sensitivity and specificity; radiopharmaceuticals; reproducibility; reproducibility of results; computer assisted tomography; image interpretation, computer-assisted; incidence; tomography, x-ray computed; diagnostic imaging; biotechnology; radiography, thoracic; statistical analysis; abdomen; radiologist; image enhancement; subtraction technique; image quality; fluorodeoxyglucose f 18; fluorodeoxyglucose f18; positron-emission tomography; medical specialist; artifact; artifacts; respiratory mechanics; pet/ct; radiography, abdominal; equipment; thorax; frequency analysis; equipment failure analysis; spiral computer assisted tomography; breathing; movement; whole body tomography; transducers; multi-row ct; respiration artifacts
Journal Title: European Journal of Nuclear Medicine and Molecular Imaging
Volume: 32
Issue: 12
ISSN: 1619-7070
Publisher: Springer  
Date Published: 2005-12-01
Start Page: 1429
End Page: 1439
Language: English
DOI: 10.1007/s00259-005-1879-8
PUBMED: 16133383
PROVIDER: scopus
DOI/URL:
Notes: --- - "Cited By (since 1996): 36" - "Export Date: 24 October 2012" - "CODEN: EJNMA" - "Source: Scopus"
Altmetric
Citation Impact
BMJ Impact Analytics
MSK Authors
  1. Heiko Schoder
    543 Schoder