An analysis of the utility of handheld PET probes for the intraoperative localization of malignant tissue Journal Article


Authors: González, S. J.; Gonzalez, L.; Wong, J.; Brader, P.; Zakowski, M.; Gonen, M.; Daghighian, F.; Fong, Y.; Strong, V. E.
Article Title: An analysis of the utility of handheld PET probes for the intraoperative localization of malignant tissue
Abstract: Introduction: The intraoperative localization of suspicious lesions detected by positron emission tomography (PET) scan remains a challenge. To solve this, two novel probes have been created to accurately detect the 18F-FDG radiotracer intraoperatively. Methods: Nude rats were inoculated with mesothelioma. When PET scans detected 10-mm tumors, animals were dissected and the PET probes analyzed the intraoperative radiotracer uptake of these lesions as tumor to background ratio (TBR). Results: The 17 suspicious lesions seen on PET scan were localized intraoperatively (by their high TBR) using the PET probes and found malignant on pathology. Interestingly, smaller tumors not visualized on PET scan were detected intraoperatively by their high TBR and found malignant on pathology. Furthermore, using a TBR threshold as low as 2.0, both gamma (sensitivity, 100%; specificity, 80%; positive predictive value (PPV), 96%; and negative predictive value (NPV), 100%) and beta (sensitivity, 100%; specificity, 60%; PPV, 93%; and NPV, 100%) probes reliably detected suspicious lesions on PET scan imaging. They also showed an excellent area under the curve of 0.9 and 0.97 (95% CI of 0.81-0.99 and 0.93-1.0) for gamma and beta probes, respectively, in the receiver operating characteristic analysis for detecting malignancy. Conclusion: This novel tool could be used synergistically with a PET scan imaging to maximize tissue selection intraoperatively. © 2010 The Society for Surgery of the Alimentary Tract.
Keywords: minimally invasive surgery; beta rays; high-energy gamma rays; intraoperative probe; pet probe
Journal Title: Journal of Gastrointestinal Surgery
Volume: 15
Issue: 2
ISSN: 1091-255X
Publisher: Springer  
Date Published: 2011-02-01
Start Page: 358
End Page: 366
Language: English
DOI: 10.1007/s11605-010-1394-5
PROVIDER: scopus
PUBMED: 21108016
PMCID: PMC3275348
DOI/URL:
Notes: --- - "Export Date: 4 March 2011" - "Source: Scopus"
Altmetric
Citation Impact
BMJ Impact Analytics
MSK Authors
  1. Mithat Gonen
    1031 Gonen
  2. Peter Brader
    25 Brader
  3. Maureen F Zakowski
    289 Zakowski
  4. Yuman Fong
    775 Fong
  5. Vivian Strong
    268 Strong
  6. Joyce Wong
    16 Wong