PET quantification inaccuracy of non-uniform tracer distributions for radiation therapy Conference Paper


Authors: Kirov, A. S.; Danford, C.; Schmidtlein, C. R.; Yorke, E.; Humm, J. L.; Amols, H. I.
Title: PET quantification inaccuracy of non-uniform tracer distributions for radiation therapy
Conference Title: 2007 IEEE Nuclear Science Symposium and Medical Imaging Conference
Abstract: The quantitative accuracy of PET has been measured for phantoms containing uniform activity spheres and cylinders, but has never been studied for non-uniformly varying tracer concentration (TC) distributions. For the correct delineation of tumors for radiation therapy (RT) using PET, the combined effect of all PET image degrading factors for realistic cases needs to be known. We investigate PET inaccuracy for a phantom with TC and attenuation varying non-uniformly in one direction. This 1D model enables determination of the positional, angular and statistical effects on the quantification accuracy. We simulated a cylindrical uniform TC phantom containing a non-uniform TC insert using the GATE (Geant4 Application for Tomographic Emission) Monte Carlo code. The insert is made of thin parallel slabs with different TC, atomic composition and density. The phantom is simulated inside a validated model of the GE Discovery LS PET/CT scanner. The Software for Tomographic Image Reconstruction (STIR) was used to reconstruct the PET images, which were then analyzed by comparing the reconstructed to true TC recovery coefficients. Simulated images with and without attenuation (AC) and scatter and random events included and rejected were analyzed. The results showed that for strongly non-uniform attenuation and adequate statistics, very accurate attenuation, scatter and random corrections are needed to achieve accuracy better than 20% for most voxels, except close to regions with high gradient, where larger differences are seen. Insufficient scatter and random corrections lead to underestimation of the TC in regions with low attenuation. In such cases, tumors in the lung and close to the end of the axial FOV and with low statistics may not be seen. Reliable estimates of the quantification inaccuracy of 3D PET are needed if 3D PET is to be used for tumor segmentation and dose painting for radiation therapy. © 2007 IEEE.
Keywords: three dimensional; positron emission tomography; radiotherapy; oncology; image enhancement; medical imaging; tumors; pet imaging; image processing; image reconstruction; image segmentation; imaging techniques; statistical methods; painting; thermography (temperature measurement); attenuation; concentration (process); germanium; metal recovery; mosfet devices; plastic bottles; positron annihilation spectroscopy; random processes; 1-d models; atomic compositions; combined effects; geant4 application for tomographic emission; image degrading factors; monte carlo codes; non-uniform tracer; nuclear sciences; quantitative accuracy; random events; recovery coefficients; reliable estimates; simulated imaging; software for tomographic image reconstruction; statistical effects; tracer concentrations; tumor segmentation; validated model
Journal Title IEEE Nuclear Science Symposium Conference Record
Volume: 4
Conference Dates: 2007 Oct 27-Nov 3
Conference Location: Honolulu, HI
ISBN: 1095-7863
Publisher: IEEE  
Date Published: 2007-01-01
Start Page: 2838
End Page: 2841
Language: English
DOI: 10.1109/NSSMIC.2007.4436727
PROVIDER: scopus
DOI/URL:
Notes: --- - IEEE Nuclear Science Symposium Conference Record - IEEE Nucl. Sci. Symp. Conf. Rec. - "Conference code: 72848" - "Export Date: 17 November 2011" - "Art. No.: 4436727" - "CODEN: 85OQA" - "Sponsors: Nuclear and Plasma Sciences Society of IEEE" - 27 October 2007 through 3 November 2007 - "Source: Scopus"
Altmetric
Citation Impact
BMJ Impact Analytics
MSK Authors
  1. Ellen D Yorke
    450 Yorke
  2. Howard I Amols
    157 Amols
  3. John Laurence Humm
    433 Humm
  4. Assen Kirov
    89 Kirov