ADC measurements on the Unity MR-linac: A recommendation on behalf of the Elekta Unity MR-linac Consortium Journal Article


Authors: Kooreman, E. S.; van Houdt, P. J.; Keesman, R.; Pos, F. J.; van Pelt, V. W. J.; Nowee, M. E.; Wetscherek, A.; Tijssen, R. H. N.; Philippens, M. E. P.; Thorwarth, D.; Wang, J.; Shukla-Dave, A.; Hall, W. A.; Paulson, E. S.; van der Heide, U. A.
Article Title: ADC measurements on the Unity MR-linac: A recommendation on behalf of the Elekta Unity MR-linac Consortium
Abstract: Background and purpose: Diffusion-weighted imaging (DWI) for treatment response monitoring is feasible on hybrid magnetic resonance linear accelerator (MR-linac) systems. The MRI scanner of the Elekta Unity system has an adjusted design compared to diagnostic scanners. We investigated its impact on measuring the DWI-derived apparent diffusion coefficient (ADC) regarding three aspects: the choice of b-values, the spatial variation of the ADC, and scanning during radiation treatment. The aim of this study is to give recommendations for accurate ADC measurements on Unity systems. Materials and methods: Signal-to-noise ratio (SNR) measurements with increasing b-values were done to determine the highest bvalue that can be measured reliably. The spatial variation of the ADC was assessed on six Unity systems with a cylindrical phantom of 40 cm diameter. The influence of gantry rotation and irradiation was investigated by acquiring DWI images before and during treatment of 11 prostate cancer patients. Results: On the Unity system, a maximum b-value of 500 s/mm2 should be used for ADC quantification, as a trade-off between SNR and diffusion weighting. Accurate ADC values were obtained within 7 cm from the iso-center, while outside this region ADC values deviated more than 5%. The ADC was not influenced by the rotating linac or irradiation during treatment. Conclusion: We provide Unity system specific recommendations for measuring the ADC. This will increase the consistency of ADC values acquired in different centers on the Unity system, enabling large cohort studies for biomarker discovery and treatment response monitoring. © 2020 Elsevier B.V.
Keywords: diffusion weighted imaging; recommendation; adc; dwi; mr-linac
Journal Title: Radiotherapy and Oncology
Volume: 153
ISSN: 0167-8140
Publisher: Elsevier Inc.  
Date Published: 2020-12-01
Start Page: 106
End Page: 113
Language: English
DOI: 10.1016/j.radonc.2020.09.046
PUBMED: 33017604
PROVIDER: scopus
PMCID: PMC8327388
DOI/URL:
Notes: Article -- Export Date: 4 January 2021 -- Source: Scopus
Altmetric
Citation Impact
BMJ Impact Analytics
MSK Authors
  1. Amita Dave
    137 Dave