Model selection for high b-value diffusion-weighted MRI of the prostate Journal Article


Authors: Mazaheri, Y.; Hötker, A. M.; Shukla-Dave, A.; Akin, O.; Hricak, H.
Article Title: Model selection for high b-value diffusion-weighted MRI of the prostate
Abstract: Purpose: To assess the abilities of the standard mono-exponential (ME), bi-exponential (BE), diffusion kurtosis (DK) and stretched exponential (SE) models to characterize diffusion signal in malignant and prostatic tissues and determine which of the four models best characterizes these tissues on a per-voxel basis.& para;& para;Materials and methods: This institutional-review-board-approved, HIPAA-compliant, retrospective study included 55 patients (median age, 61 years; range, 42-77 years) with untreated, biopsy-proven PCa who underwent endorectal coil MRI at 3-Tesla, diffusion-weighted MRI acquired at eight b-values from 0 to 2000 s/mm(2). Estimated parameters were apparent diffusion coefficent (ME model); diffusion coefficients for the fast (D-fast) and slow (D-slow) components and fraction of fast component, f(fast) (BE model); diffusion coefficient D, and kurtosis K (DK model); distributed diffusion coefficient DDC and a for (SE model). For one region-of-interest (ROI) in PZ and another in PCa in each patient, the corrected Akaike information criterion (AICc) and the Akaike weight (w) were calculated for each voxel.& para;& para;Results: Based on AICc and w, all non-monoexponential models outperformed the ME model in PZ and PCa. The DK model in PZ and SE model in PCa ROIs best fit the greatest average percentages of voxels (39% and 43%, respectively) and had the highest mean w (35 +/- 16 x 10(-2) and 41 +/- 22 x 10(-2), respectively).& para;& para;Conclusion: DK and SE models best fit DWI data in PZ and PCa, and non-ME models consistently outperformed the ME model. Voxel-wise mapping of the preferential model demonstrated that the vast majority of voxels in either tissue type were best fit with one of the non-monoexponential models. At the given SNR levels, the maximum b-value of 2000 s/mm(2) is not sufficiently high to identify the preferred non-monoexponential model.
Keywords: aggressiveness; repeatability; water diffusion; diffusion-weighted mri (dw-mri); cancer; prostate cancer (pca); mono-exponential; model (me); bi-exponential model (be); diffusion kurtosis (dk); stretched exponential (se); different mathematical-models
Journal Title: Magnetic Resonance Imaging
Volume: 46
ISSN: 0730-725X
Publisher: Elsevier Science, Inc.  
Date Published: 2018-02-01
Start Page: 21
End Page: 27
Language: English
ACCESSION: WOS:000419426000003
DOI: 10.1016/j.mri.2017.10.003
PROVIDER: wos
PUBMED: 29031583
PMCID: PMC6638582
Notes: Article -- Source: Wos
Altmetric
Citation Impact
BMJ Impact Analytics
MSK Authors
  1. Hedvig Hricak
    419 Hricak
  2. Amita Dave
    137 Dave
  3. Oguz Akin
    264 Akin
  4. Andreas Markus Hoetker
    22 Hoetker