Dosimetric comparison of rectal-sparing capabilities of rectal balloon vs injectable spacer gel in stereotactic body radiation therapy for prostate cancer: Lessons learned from prospective trials Journal Article


Authors: Jones, R. T.; Hassan Rezaeian, N.; Desai, N. B.; Lotan, Y.; Jia, X.; Hannan, R.; Kim, D. W. N.; Hornberger, B.; Dubas, J.; Laine, A. M.; Zelefsky, M. J.; Timmerman, R. D.; Folkert, M. R.
Article Title: Dosimetric comparison of rectal-sparing capabilities of rectal balloon vs injectable spacer gel in stereotactic body radiation therapy for prostate cancer: Lessons learned from prospective trials
Abstract: This study aimed to compare the rectal-sparing capabilities of rectal balloons vs absorbable injectable spacer gel in stereotactic body radiation therapy (SBRT) for prostate cancer. Patient samples included in this analysis were obtained from 2 multi-institutional prospective trials of SBRT for prostate cancer using a rectal balloon (n = 36 patients) and injectable spacer gel (n = 36). Treatment prescription dose was 45 Gy in 5 fractions in 42 patients; for equal comparison, the remaining 30 patients were rescaled to 45 Gy from 47.5 Gy prescription (n = 6) and 50 Gy prescription (n = 24). The median prostate volumes and body mass index in the 2 patient samples were not statistically significantly different (p = 0.67 and 0.45, respectively), supporting anatomic similarity between cohorts. The injectable spacer gel achieved dosimetric superiority over the rectal balloon with respect to the maximum dose to the rectum (42.3 vs 46.2 Gy, p < 0.001), dose delivered to 33% of the rectal circumference (28 vs 35.1 Gy, p < 0.001), and absolute volume of rectum receiving 45 Gy (V45Gy), V40Gy, and V30Gy (0.3 vs 1.7 cc, 1 vs 5.4 cc, and 4.1 vs 9.6 cc, respectively; p < 0.001 in all cases). There was no difference between the 2 groups with respect to the V50Gy of the rectum or the dose to 50% of the rectal circumference (p = 0.29 and 0.06, respectively). The V18.3Gy of the bladder was significantly larger with the rectal balloon (19.9 vs 14.5 cc, p = 0.003). In this analysis of patients enrolled on 2 consecutive multi-institutional prospective trials of SBRT for prostate cancer, the injectable spacer gel outperformed the rectal balloon in the majority of the examined and relevant dosimetric rectal-sparing parameters. The rectal balloon did not outperform the injectable spacer gel in any measured rectal dose parameter. © 2017 American Association of Medical Dosimetrists
Keywords: major clinical study; comparative study; prospective study; cohort analysis; prostate cancer; prescription; body mass; dosimetry; radiation dose fractionation; conservative treatment; multicenter study; stereotactic body radiation therapy; rectum surgery; bladder function; rectal toxicity; maximum permissible dose; prostate volume; rectal balloon; human; male; priority journal; article; rectal dosimetry; rectal spacer
Journal Title: Medical Dosimetry
Volume: 42
Issue: 4
ISSN: 0958-3947
Publisher: Elsevier Science, Inc.  
Date Published: 2017-01-01
Start Page: 341
End Page: 347
Language: English
DOI: 10.1016/j.meddos.2017.07.002
PROVIDER: scopus
PUBMED: 28774760
DOI/URL:
Notes: The publisher's record lists the publication date as Winter -- Article -- Export Date: 2 January 2018 -- Source: Scopus
Altmetric
Citation Impact
BMJ Impact Analytics
MSK Authors
  1. Michael J Zelefsky
    754 Zelefsky