The effect of significant tumor reduction on the dose distribution in intensity modulated radiation therapy for head-and-neck cancer: A case study Journal Article


Authors: Mechalakos, J.; Lee, N.; Hunt, M.; Ling, C. C.; Amols, H. I.
Article Title: The effect of significant tumor reduction on the dose distribution in intensity modulated radiation therapy for head-and-neck cancer: A case study
Abstract: We present a unique case in which a patient with significant tissue loss was monitored for dosimetric changes using weekly cone beam computed tomography (CBCT) scans. A previously treated nasopharynx patient presented with a large, exophytic, recurrent left neck mass. The patient underwent re-irradiation to 70 Gy using intensity modulated radiation therapy (IMRT) with shielding blocks over the spinal cord and brain stem. Weekly CBCT scans were acquired during treatment. Target contours and treatment fields were then transferred from the original treatment planning computed tomography (CT) to the CBCT scans and dose calculations were performed on all CBCT scans and compared to the planning doses. In addition, a "research" treatment plan was created that assumed the patient had not been previously treated, and the above analysis was repeated. Finally, to remove the effects of setup error, the outer contours of 2 CBCT scans with significant tumor reductions were transferred to the planning scan and dose in the planning scan was recalculated. Planning treatment volume (PTV) decreased 45% during treatment. Spinal cord D05 differed from the planned value by 3.5 ± 9.8% (average + standard deviation). Mean dose to the oral cavity and D05 of the mandible differed from the planned value by 0.9 ± 2.1% and 0.6 ± 1.5%, respectively. Results for the research plan were comparable. Target coverage did not change appreciably (-0.2 ± 2.5%). When the planning scan was recalculated with the reduced outer contour from the CBCT, spinal cord D05 decreased slightly due to the reduction in scattered dose. Weekly imaging provided us the unique opportunity to use different methods to examine the dosimetric effects of an unusually large loss of tissue. We did not see that tissue loss alone resulted in a significant effect on the dose delivered to the spinal cord for this case, as most fluctuation was due to setup error. In the IGRT era, delivered dose distributions can be more readily determined during treatment, and this information can be useful in deciding whether replanning is necessary. © 2009 American Association of Medical Dosimetrists.
Keywords: case report; intensity modulated radiation therapy; treatment planning; cancer radiotherapy; radiation dose; computer assisted tomography; radiotherapy dosage; dose-response relationship, radiation; head and neck cancer; imrt; dosimetry; spinal cord; radiometry; radiotherapy planning, computer-assisted; radiotherapy, conformal; dose fractionation; nasopharyngeal neoplasms; radiation dose distribution; igrt; brain stem; head and neck; cone beam computed tomography; planning; error; histogram; mandible; mouth cavity; radiation scattering; radiation shield
Journal Title: Medical Dosimetry
Volume: 34
Issue: 3
ISSN: 0958-3947
Publisher: Elsevier Science, Inc.  
Date Published: 2009-01-01
Start Page: 250
End Page: 255
Language: English
DOI: 10.1016/j.meddos.2008.10.004
PUBMED: 19647637
PROVIDER: scopus
PMCID: PMC2892776
DOI/URL:
Notes: The publisher's record lists the publication date as Autumn -- "Cited By (since 1996): 1" -- "Export Date: 30 November 2010" -- "CODEN: MEDOE" -- "Source: Scopus"
Altmetric
Citation Impact
BMJ Impact Analytics
MSK Authors
  1. Nancy Y. Lee
    876 Lee
  2. Howard I Amols
    157 Amols
  3. Margie A Hunt
    287 Hunt
  4. C Clifton Ling
    331 Ling