Interventional C-arm tomosynthesis for vascular imaging: Initial results Conference Paper


Authors: Langan, D. A.; Claus, B. E. H.; Al Assad, O.; Trousset, Y.; Riddell, C.; Avignon, G.; Solomon, S. B.; Lai, H.; Wang, X.
Editors: Kontos, D.; Hoeschen, C.
Title: Interventional C-arm tomosynthesis for vascular imaging: Initial results
Conference Title: Medical Imaging 2015: Physics of Medical Imaging
Abstract: As percutaneous endovascular procedures address more complex and broader disease states, there is an increasing need for intra-procedure 3D vascular imaging. In this paper, we investigate C-Arm 2-axis tomosynthesis ("Tomo"?) as an alternative to C-Arm Cone Beam Computed Tomography (CBCT) for workflow situations in which the CBCT acquisition may be inconvenient or prohibited. We report on our experience in performing tomosynthesis acquisitions with a digital angiographic imaging system (GE Healthcare Innova 4100 Angiographic Imaging System, Milwaukee, WI). During a tomo acquisition the detector and tube each orbit on a plane above and below the table respectively. The tomo orbit may be circular or elliptical, and the tomographic half-angle in our studies varied from approximately 16 to 28 degrees as a function of orbit period. The trajectory, geometric calibration, and gantry performance are presented. We overview a multi-resolution iterative reconstruction employing compressed sensing techniques to mitigate artifacts associated with incomplete data reconstructions. In this work, we focus on the reconstruction of small high contrast objects such as iodinated vasculature and interventional devices. We evaluate the overall performance of the acquisition and reconstruction through phantom acquisitions and a swine study. Both tomo and comparable CBCT acquisitions were performed during the swine study thereby enabling the use of CBCT as a reference in the evaluation of tomo vascular imaging. We close with a discussion of potential clinical applications for tomo, reflecting on the imaging and workflow results achieved. © 2015 SPIE.
Keywords: computerized tomography; medical imaging; tomography; image reconstruction; cone-beam computed tomography; tomosynthesis; imaging systems; iterative reconstruction; 3D reconstruction; compressed sensing; iterative methods; interventional; endovascular procedures; interventional c-arm; vascular imaging; robotic arms; geometric calibrations
Journal Title Proceedings of SPIE
Volume: 9412
Conference Dates: 2015 Feb 22-25
Conference Location: Orlando, FL
ISBN: 0277-786X
Publisher: SPIE  
Date Published: 2015-03-18
Start Page: 94125N
Language: English
DOI: 10.1117/12.2081195
PROVIDER: scopus
DOI/URL:
Notes: Progr. Biomed. Opt. Imaging Proc. SPIE -- Conference code: 112273 -- Cited By :1 -- Export Date: 2 November 2015 -- ALIO Industries; Alpinion Medical Systems; Bruker; et al.; Modus Medical Devices Inc.; The Society of Photo-Optical Instrumentation Engineers (SPIE) -- 22 February 2015 through 25 February 2015 -- Source: Scopus