Detection of lymph node metastasis in patients with nodal prostate cancer relapse using 18F/11C-choline positron emission tomography/computerized tomography Journal Article


Authors: Jilg, C. A.; Schultze-Seemann, W.; Drendel, V.; Vach, W.; Wieser, G.; Krauss, T.; Jandausch, A.; Hölz, S.; Henne, K.; Reske, S. N.; Grosu, A. L.; Weber, W. A.; Rischke, H. C.
Article Title: Detection of lymph node metastasis in patients with nodal prostate cancer relapse using 18F/11C-choline positron emission tomography/computerized tomography
Abstract: Purpose: We evaluated the diagnostic accuracy of choline positron emission tomography/computerized tomography for nodal relapse of prostate cancer according to topographical site and tumor infiltration size in lymph nodes. Materials and Methods: A total of 72 patients with nodal prostate cancer relapse after primary therapy underwent pelvic and/or retroperitoneal salvage lymph node dissection. Salvage was done after whole body positron emission tomography/computerized tomography with 11C-choline or 18F-fluoroethylcholine showed positron emission tomography positive lymph nodes but no other detectable metastasis. Diagnostic accuracy was evaluated in 160 dissected lymph node regions (pelvic left/right and retroperitoneal), 498 subregions (common, external and internal iliac, obturator, presacral, aortic bifurcation, aortal, vena caval and interaortocaval) and 2,122 lymph nodes. Results: Lymph node metastasis was present in 32% of resected lymph nodes (681 of 2,122), resulting in 238 positive subregions and 111 positive regions. Positron emission tomography/computerized tomography was positive for 110 regions and 209 subregions. Sensitivity, specificity, positive and negative predictive values, and accuracy were 91.9%, 83.7%, 92.7%, 82.0% and 89.4% (region based), 80.7%, 93.5%, 91.9%, 84.1% and 87.3% (subregion based), and 57.0%, 98.4%, 94.5%, 82.6% and 84.9% (lesion based), respectively. Of 393 positive lymph node metastases detected by this method 278 (70.7%) were in lymph nodes with a less than 10 mm short axis diameter. Imaging sensitivity was 13.3%, 57.4% and 82.8% for a tumor infiltration depth of 2 or greater to less than 3 mm, 5 or greater to less than 6 mm and 10 or greater to less than 11 mm, respectively. Lymph node metastasis site and the radiotracer (11C-choline/18F- fluoroethylcholine) had no substantial impact on diagnostic accuracy. Conclusions: Choline positron emission tomography/computerized tomography detects affected lymph node regions (pelvic left/right and retroperitoneal) in patients with prostate cancer relapse with high accuracy and it seems helpful for guiding salvage lymph node dissection. Sensitivity decreases with the size of metastatic infiltration in lymph nodes. This technique detects metastasis in a significant fraction of lymph nodes that are not pathologically enlarged on computerized tomography. © 2014 by American Urological Association Education and Research, Inc.
Keywords: lymph node dissection; prostate; computerized tomography; positron-emission tomography; neoplasm metastasis; emission-computed
Journal Title: Journal of Urology
Volume: 192
Issue: 1
ISSN: 0022-5347
Publisher: Elsevier Science, Inc.  
Date Published: 2014-07-01
Start Page: 103
End Page: 110
Language: English
DOI: 10.1016/j.juro.2013.12.054
PROVIDER: scopus
PUBMED: 24518792
DOI/URL:
Notes: J. Urol. -- Export Date: 8 July 2014 -- CODEN: JOURA -- Source: Scopus
Altmetric
Citation Impact
BMJ Impact Analytics
MSK Authors
  1. Wolfgang Andreas Weber
    173 Weber