Distribution of reported starclose SE vascular closure device complications in the manufacturer and user facility device experience database Journal Article


Authors: Johnson, D. T.; Durack, J. C.; Fidelman, N.; Kerlan, R. K.; Laberge, J. M.
Article Title: Distribution of reported starclose SE vascular closure device complications in the manufacturer and user facility device experience database
Abstract: Purpose To evaluate the type and frequency of complications associated with the StarClose SE vascular closure device reported to the U.S. Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database for comparison with complications reported in clinical trials. Materials and Methods Complications reported in the MAUDE database related to use of the StarClose SE vascular closure device were reviewed. Keyword searches by device and manufacturer were performed for a 16-month period from July 2009-October 2010. Reports were analyzed according to complication type, frequency, and resolution, if specified. These data were compared with data on StarClose SE device complications, which included three prospective randomized trials and five prospective nonrandomized trials. Results Keyword searches returned 1,107 total records and 1,118 categorizable StarClose SE device complications from the 16-month MAUDE database-reporting period. Complications in order of frequency (absolute number and relative frequency, respectively) included failure to achieve hemostasis (409, 36.6%), inability to complete the deployment sequence (268, 24.0%), entrapped deployment device (224, 20%), clip not deployed (151,13.5%), late bleeding or oozing from dermatotomy site (25, 2.2%), vessel occlusion (19, 1.7%), retroperitoneal hematoma (12, 1.1%), pseudoaneurysm formation (6, 0.5%) and death (4, 0.4%). The distribution of complications differed appreciably from the combined adverse events compiled from the published trials evaluating the StarClose SE device. There were no records describing inability to remove the deployment device in the published trials, whereas this represented the third most common complication reported to the MAUDE database. Bleeding or oozing from the dermatotomy site, the most frequent relative complication reported in the published literature (53.4%), represented 2.2% of the total complications reported to the MAUDE database. Conclusions The type and frequency of complications reported in the MAUDE database on the StarClose SE vascular closure device differ from those published in clinical trials both in relative distribution and in type. Although these differences may reflect in part reporting biases, the distribution of complications reported to the MAUDE database may represent useful information in the use of this device. © 2013 SIR.
Keywords: heart infarction; nerve injury; surgical mortality; postoperative hemorrhage; hemostasis; groin hematoma; randomized controlled trial (topic); artery occlusion; artery dissection; false aneurysm; retroperitoneal hemorrhage; blood vessel occlusion; retroperitoneal hematoma; blood vessel clip; medical device complication
Journal Title: Journal of Vascular and Interventional Radiology
Volume: 24
Issue: 7
ISSN: 1051-0443
Publisher: Elsevier Science, Inc.  
Date Published: 2013-07-01
Start Page: 1051
End Page: 1056
Language: English
DOI: 10.1016/j.jvir.2013.03.032
PROVIDER: scopus
PUBMED: 23796092
DOI/URL:
Notes: --- - "Export Date: 1 August 2013" - "CODEN: JVIRE" - "Source: Scopus"
Altmetric
Citation Impact
BMJ Impact Analytics
MSK Authors
  1. Jeremy Charles Durack
    116 Durack