Liposome-mediated radiotherapeutics within avascular tumor spheroids: Comparative dosimetry study for various radionuclides, liposome systems, and a targeting antibody Journal Article


Authors: Emfietzoglou, D.; Kostarelos, K.; Papakostas, A.; Yang, W. H.; Ballangrud, A.; Song, H.; Sgouros, G.
Article Title: Liposome-mediated radiotherapeutics within avascular tumor spheroids: Comparative dosimetry study for various radionuclides, liposome systems, and a targeting antibody
Abstract: Absorbed dose profiles within tumor spheroids simulating avascular micrometastases have been calculated for a variety of liposome- and antibody-radionuclide combinations to assess the anticipated therapeutic efficacy based on the intratumoral distribution of the carrier systems within the spheroid model. Methods: Experiments studying the targeting and diffusion capability of the most clinically relevant liposome systems and the anti-PSMA (prostate-specific membrane antigen) antibody J591 within spheroids of the prostate cancer cell line LNCaP (diameter, 150-200 μm) have been performed. The intratumoral biodistribution data were then used as the input to obtain absorbed dose profiles within the tumor spheroid mass. The dosimetric analysis was performed for a variety of medium- and high-energy β-emitting radionuclides ( 32P, 90Y, 188Re, 57Cu, 131I) and 2 low-energy Auger or conversion electron emitters ( 123I, 125I) following the point-kernel convolution method in the continuous slowing-down approximation. Results: Relative absorbed dose distribution calculations as a function of the distance from the rim of the spheroids are presented. For all liposome systems studied, the SUV-DMPC-chol (small unilamellar vesicle-dimyristoyl-phosphatidylcholine- cholesterol) was most efficient in penetrating deeper within the spheroids. For the β-emitters it delivered its maximum absorbed dose (D max) at 40- to 50-μm depth, exhibiting an almost flat absorbed dose profile beyond that point, as is evident by the high absorbed dose value at the center of the spheroid (D core), D core/D max > 0.9; the respective values for the J591 antibody were 20 antibody and 0.85. The Auger or conversion emitters resulted in the most heterogeneous absorbed dose distribution; the ratio D core/D max fell to 0.4 for the SUV-DMPC-chol and to 0.4-0.5 for the antibody. In general, a 2- to 10-fold "cross-fire"-related increase of the core absorbed dose was observed. For liposomes exhibiting high binding capacity (3β-[N-(N′,N′]- dimethylaminoethane)carbamoyl]cholesterol [DC-chol]), however, the low-energy emitters deliver up to a 40% higher D max relative to the β-emitters. The surface characteristics of liposomes appear to have a noticeable influence on the absorbed dose profiles. The use of neutral (DMPC-chol) versus cationic (DC-chol) lipids resulted in up to a 10-fold increase of D core/D max depending on the radionuclide. Changing the cationic lipid used to N-[1-(2,3-dioleoyloxy)propyl]-N,N,N- trimethylammonium methyl sulfate also had a notable influence (up to a 6-fold increase), whereas the effect of fusogenic lipids (dioleoylphosphatidylcholine) was found to be much smaller. Conclusion: It is possible to engineer liposome systems that are particularly effective in delivering an almost uniform absorbed dose profile at the central region of micrometastatic tumors, provided that conjugates with the appropriate radionuclides are constructed. In view of the passive means of diffusion of liposomes within solid tumors, it is suggested that they may effectively complement an antibody-based therapeutic regime against micrometastatic tumors, leading to cytotoxic absorbed dose levels throughout the entire tumor volume-thus, hindering tumor recurrence.
Keywords: human cell; comparative study; radiation dose; methodology; radiopharmaceuticals; metabolism; radiotherapy dosage; radiotherapy; lipid; cell line, tumor; radiation exposure; monoclonal antibody; prostate cancer; drug delivery systems; prostatic neoplasms; monoclonal antibody j591; prostate specific membrane antigen; antibodies, monoclonal; iodine 125; iodine 131; evaluation; dosimetry; prostate tumor; tumor cell line; radiopharmaceutical agent; micrometastasis; radiometry; radioisotope; drug half life; radioisotopes; radiation dose distribution; antibody; liposome; drug delivery system; liposomes; cell strain lncap; spheroids, cellular; yttrium 90; multicellular spheroid; spheroids; iodine 123; radionuclides; phosphorus 32; dioleoylphosphatidylcholine; liposome systems; radiotherapeutics; copper 67; tumor spheroid
Journal Title: Journal of Nuclear Medicine
Volume: 46
Issue: 1
ISSN: 0161-5505
Publisher: Society of Nuclear Medicine  
Date Published: 2005-01-01
Start Page: 89
End Page: 97
Language: English
PROVIDER: scopus
PUBMED: 15632038
DOI/URL:
Notes: --- - "Cited By (since 1996): 22" - "Export Date: 24 October 2012" - "CODEN: JNMEA" - "Source: Scopus"
Citation Impact