Tattoo-less chest wall and regional nodal irradiation using surface imaging Journal Article


Authors: Mueller, B.; Song, Y.; Zhai, X.; Liang, Y.; Tamas, P.; Powell, S.; Guttmann, D. M.; Roth O'Brien, D.; McCormick, B.; Khan, A.; Cervino-Arriba, L.; Zhao, B.; Hong, L.; Braunstein, L. Z.
Article Title: Tattoo-less chest wall and regional nodal irradiation using surface imaging
Abstract: Purpose/Objective: Skin tattoos represent the standard for surface alignment and setup of breast cancer radiotherapy yet contribute to adverse cosmesis and patient dissatisfaction. With the advent of contemporary surface imaging technology, we evaluated setup accuracy, time, and dosimetric parameters between traditional tattoo-based setup techniques and a “tattoo-less” approach for lymph node positive and high-risk breast cancer patients requiring chest wall and regional nodal radiation. Material/Methods Patients receiving chest wall radiation for breast cancer underwent a traditional tattoo-based setup (TTB), alternating daily with a tattoo-less setup via surface imaging using AlignRT (ART) to serve as an internal control. Following initial setup (using tattoos or AlignRT), target position was verified by daily kV imaging, with matching on the chest wall bony anatomy representing ground truth. Translational (TS) and rotational shifts (RS) were ascertained, as were setup time and total in-room time. Delivered dosimetry was calculated using the reverse isocenter shift technique. Statistical analyses used the Wilcoxon Signed Rank test and Pitman-Morgan variance test. Results: A total of 49 breast cancer patients receiving a total of 1118 fractions (n = 560 for ART and 558 for TTB) of chest wall radiation were analyzed. For tattoo-less setup via ART, the median absolute TS was 0.28 cm vertical (range: 0.14–––0.48), 0.24 cm lateral (0.10–––0.40), and 0.26 cm longitudinal (0.13––0.44). For TTB setup, the corresponding median TS were 0.34 cm (0.15–––0.52), 0.29 (0.13–––0.46), and 0.34 cm (0.14–––0.59), respectively. ART was significantly more accurate than TTB with regard to TS (p = 0.038, 0.007, <0.001, respectively). Variance testing also showed increased precision with ART in the vertical (p < 0.001) and longitudinal (p < 0.001) axes. The median absolute RS for ART was 0.80° rotational (range:0.40–1.50), 0.60° roll (0.20–1.20), and 0.50° pitch (0.10–1.00). The corresponding median RS for TTB was 1.00° (0.40–1.70), 0.60° (0.20–1.20), and 0.50° (0.10–1.00). ART was significantly more accurate for RS than TTB (p = 0.023). ART setup was otherwise not statistically different from TTB regarding roll and pitch (p = 0.558, 0.929, respectively). ART showed no difference in precision versus TTB regarding RS, pitch, and roll (p = 0.181, p = 0.544, p = 0.858). The median total in-room time for ART was 18.77 min (range: 16.04–20.77) and 18.70 min (17.58–20.67) for TTB (p = 0.38). The median setup time was 12.75 min (11.43–14.80) for ART and 13.78 min (12.42–15.09) for TTB (p = 0.054). There was no significant difference between the AlignRT and the tattoo-based methods for both setup and in-room time. Conclusion: These findings indicate that utilizing the tattoo-less setup method with AlignRT provides sufficient accuracy and speed to potentially supplant the use of surface tattoos in lymph node positive and high-risk breast cancer patients requiring chest wall and regional lymph node radiation. Further investigations involving larger patient cohorts will further inform whether surface imaging can wholly replace tattoo-based approaches. © 2025 The Author(s)
Keywords: adult; clinical article; controlled study; cancer surgery; cancer radiotherapy; computer assisted tomography; breast cancer; mastectomy; dosimetry; breath holding; thorax wall; lumpectomy; volumetric modulated arc therapy; tattooing; human; female; article; supraclavicular lymph node; surface imaging; alignrt; tattoo-less; rotating shift
Journal Title: Technical Innovations and Patient Support in Radiation Oncology
Volume: 34
ISSN: 24056324
Publisher: The Author(s)  
Date Published: 2025-06-01
Start Page: 100310
Language: English
DOI: 10.1016/j.tipsro.2025.100310
PROVIDER: scopus
PMCID: PMC12127614
PUBMED: 40458590
DOI/URL:
Notes: The MSK Cancer Center Support Grant (P30 CA008748) is acknowledged in the PDF. Corresponding MSK author is Lior Z. Braunstein -- Source: Scopus
Altmetric
Citation Impact
BMJ Impact Analytics
MSK Authors
  1. Simon Nicholas Powell
    331 Powell
  2. Boris A Mueller
    104 Mueller
  3. Linda Xueqi Hong
    88 Hong
  4. Yulin Song
    116 Song
  5. Beryl McCormick
    371 McCormick
  6. Atif Jalees Khan
    152 Khan
  7. Paul Tamas
    10 Tamas
  8. Bo Zhao
    9 Zhao
  9. Xingchen Zhai
    10 Zhai
  10. Yubei Liang
    6 Liang