Multi-institutional experience treating patients with cardiac devices on a 1.5 Tesla magnetic resonance-linear accelerator and workflow development for thoracic treatments Journal Article


Authors: Keesman, R.; van der Bijl, E.; Kerkmeijer, L. G. W.; Tyagi, N.; Akdag, O.; Wolthaus, J. W. H.; van de Pol, S. M. G.; Noteboom, J. L.; Intven, M. P. W.; Fast, M. F.; van Lier, A. L. H. M. W.
Article Title: Multi-institutional experience treating patients with cardiac devices on a 1.5 Tesla magnetic resonance-linear accelerator and workflow development for thoracic treatments
Abstract: Background and purpose: Patients with cardiac implantable electronic devices (CIED patients) are often ineligible for online magnetic resonance-guided radiotherapy (MRgRT), most likely due to the absence of established guidelines. Existing radiotherapy (RT) and magnetic resonance imaging (MRI) guidelines offer an opportunity to construct MRgRT protocols, promoting equitable access. Our objective was to present such a workflow, share multi-institutional experiences treating CIED patients with MRgRT on a 1.5 T magnetic resonance-linear accelerator (MR-linac), and investigate geometric accuracy and electrocardiogram (ECG) monitoring for thoracic treatment. Materials and methods: A risk analysis identified strategies for safe MRgRT for CIED patients. At three institutions, 21 pelvic and abdominal patients were treated. Patient records were analyzed for adverse events. Geometric accuracy was investigated using B0-mapping with a phantom simulating moving lung and cardiac lesions near a CIED. Volunteer measurements evaluated the effects of patient positioning and MRI sequences on ECG signal distortion. Results: MRI and RT workflows were adaptable to MRgRT. No adverse events were recorded. B0-maps showed a maximum mean difference between static and dynamic phantom configurations of 0.1 mm, increasing to 0.4 mm distortion in the presence of a CIED. ECG readings exhibited severe distortions during scanning, hampering heart rhythm detection for most MRI sequences. Conclusions: CIED patients can safely undergo treatment on a 1.5 T MR-linac following RT and MRI guidelines. For targets near CIEDs, a B0-mapping procedure was considered accurate enough to determine MRgRT eligibility. Pulse oximetry is recommended for cardiac monitoring during MRI scanning due to ECG signal distortion. © 2024 The Author(s)
Keywords: mr-linac; mrgrt; cied
Journal Title: Physics and Imaging in Radiation Oncology
Volume: 32
ISSN: 2405-6316
Publisher: Elsevier B.V.  
Date Published: 2024-10-01
Start Page: 100680
Language: English
DOI: 10.1016/j.phro.2024.100680
PROVIDER: scopus
PMCID: PMC11636337
PUBMED: 39668845