Patient radiation doses in interventional radiology procedures: Comparison of fluoroscopy dose indices between the American College of Radiology dose index registry-fluoroscopy pilot and the radiation doses in Interventional Radiology study Conference Paper


Authors: Jones, A. K.; Wunderle, K. A.; Fruscello, T.; Simanowith, M.; Cline, B.; Dharmadhikari, S.; Duan, X.; Durack, J. C.; Hirschl, D.; Kim, D. S.; Mahmood, U.; Mann, S. D.; Martin, C. 3rd; Metwalli, Z.; Moirano, J. M.; Neill, R. A.; Newsome, J.; Padua, H.; Schoenfeld, A. H.; Miller, D. L.
Title: Patient radiation doses in interventional radiology procedures: Comparison of fluoroscopy dose indices between the American College of Radiology dose index registry-fluoroscopy pilot and the radiation doses in Interventional Radiology study
Conference Title: 47th Annual Meeting of the Society of Interventional Radiology (SIR 2022)
Abstract: Purpose: To compare radiation dose index distributions for fluoroscopically guided interventions in interventional radiology from the American College of Radiology (ACR) Fluoroscopy Dose Index Registry (DIR-Fluoro) pilot to those from the Radiation Doses in Interventional Radiology (RAD-IR) study. Materials and Methods: Individual and grouped ACR Common identification numbers (procedure types) from the DIR-Fluoro pilot were matched to procedure types in the RAD-IR study. Fifteen comparisons were made. Distribution parameters, including the 10th, 25th, 50th, 75th, and 95th percentiles, were compared for fluoroscopy time (FT), cumulative air kerma (Ka,r), and kerma area product (PKA). Two derived indices were computed using median dose indices. The procedure-averaged reference air kerma rate (Ka,r ̄) was computed as Ka,r / FT. The procedure-averaged x-ray field size at the reference point (Ar) was computed as PKA / (Ka,r × 1,000). Results: The median FT was equally likely to be higher or lower in the DIR-Fluoro pilot as it was in the RAD-IR study, whereas the maximum FT was almost twice as likely to be higher in the DIR-Fluoro pilot than it was in the RAD-IR study. The median Ka,r was lower in the DIR-Fluoro pilot for all procedures, as was median PKA. The maximum Ka,r and PKA were more often higher in the DIR-Fluoro pilot than in the RAD-IR study. Ka,r ̄ followed the same pattern as Ka,r, whereas Ar was often greater in DIR-Fluoro. Conclusions: The median dose indices have decreased since the RAD-IR study. The typical Ka,r rates are lower, a result of the use of lower default dose rates. However, opportunities for quality improvement exist, including renewed focus on tight collimation of the imaging field of view. © 2022 SIR
Keywords: adult; conference paper; radiation dose; interventional radiology; intermethod comparison; mathematical computing; x ray; fluoroscopy; human; distribution parameters
Journal Title Journal of Vascular and Interventional Radiology
Volume: 34
Issue: 4
Conference Dates: 2022 Jun 11-16
Conference Location: Boston, MA
ISBN: 1051-0443
Publisher: Elsevier Science, Inc.  
Date Published: 2023-01-01
Start Page: 556
End Page: 562.e3
Language: English
DOI: 10.1016/j.jvir.2022.08.023
PROVIDER: scopus
PUBMED: 36031041