Authors: | Coit, D. G.; Turnbull, A. D. M. |
Article Title: | A safe technique for the placement of implantable vascular access devices in patients with thrombocytopenia |
Abstract: | This further modification of the Seldinger technique is offered as a safe and effective means of central venous access for placement of implantable infusion devices. It is especially useful in patients with severe thrombocytopenia, even when the cephalic vein is not large enough to accept the catheter directly. |
Keywords: | clinical article; methodology; thrombocytopenia; sutures; technique; prostheses and implants; catheterization, central venous; vena cava, superior; vascular access; human; male; female; priority journal |
Journal Title: | Surgery, Gynecology and Obstetrics |
Volume: | 167 |
Issue: | 5 |
ISSN: | 0039-6087 |
Publisher: | American College of Surgeons |
Date Published: | 1988-11-01 |
Start Page: | 429 |
End Page: | 431 |
Language: | English |
PUBMED: | 3175827 |
PROVIDER: | scopus |
DOI/URL: | |
Notes: | Article -- Export Date: 6 August 2020 -- Source: Scopus |