Head and neck cancer patient images for determining auto-segmentation accuracy in T2-weighted magnetic resonance imaging through expert manual segmentations Journal Article


Authors: Cardenas, C. E.; Mohamed, A. S. R.; Yang, J.; Gooding, M.; Veeraraghavan, H.; Kalpathy-Cramer, J.; Ng, S. P.; Ding, Y.; Wang, J.; Lai, S. Y.; Fuller, C. D.; Sharp, G.
Article Title: Head and neck cancer patient images for determining auto-segmentation accuracy in T2-weighted magnetic resonance imaging through expert manual segmentations
Abstract: PURPOSE: The use of magnetic resonance imaging (MRI) in radiotherapy treatment planning has rapidly increased due to its ability to evaluate patient's anatomy without the use of ionizing radiation and due to its high soft tissue contrast. For these reasons, MRI has become the modality of choice for longitudinal and adaptive treatment studies. Automatic segmentation could offer many benefits for these studies. In this work, we describe a T2-weighted MRI dataset of head and neck cancer patients that can be used to evaluate the accuracy of head and neck normal tissue auto-segmentation systems through comparisons to available expert manual segmentations. ACQUISITION AND VALIDATION METHODS: T2-weighted MRI images were acquired for 55 head and neck cancer patients. These scans were collected after radiotherapy computed tomography (CT) simulation scans using a thermoplastic mask to replicate patient treatment position. All scans were acquired on a single 1.5 T Siemens MAGNETOM Aera MRI with two large four-channel flex phased-array coils. The scans covered the region encompassing the nasopharynx region cranially and supraclavicular lymph node region caudally, when possible, in the superior-inferior direction. Manual contours were created for the left/right submandibular gland, left/right parotids, left/right lymph node level II, and left/right lymph node level III. These contours underwent quality assurance to ensure adherence to predefined guidelines, and were corrected if edits were necessary. DATA FORMAT AND USAGE NOTES: The T2-weighted images and RTSTRUCT files are available in DICOM format. The regions of interest are named based on AAPM's Task Group 263 nomenclature recommendations (Glnd_Submand_L, Glnd_Submand_R, LN_Neck_II_L, Parotid_L, Parotid_R, LN_Neck_II_R, LN_Neck_III_L, LN_Neck_III_R). This dataset is available on The Cancer Imaging Archive (TCIA) by the National Cancer Institute under the collection "AAPM RT-MAC Grand Challenge 2019" (https://doi.org/10.7937/tcia.2019.bcfjqfqb). POTENTIAL APPLICATIONS: This dataset provides head and neck patient MRI scans to evaluate auto-segmentation systems on T2-weighted images. Additional anatomies could be provided at a later time to enhance the existing library of contours. © 2019 American Association of Physicists in Medicine.
Keywords: head and neck cancer; radiation therapy; mri; automatic segmentation; grand challenge
Journal Title: Medical Physics
Volume: 47
Issue: 5
ISSN: 0094-2405
Publisher: American Association of Physicists in Medicine  
Date Published: 2020-05-01
Start Page: 2317
End Page: 2322
Language: English
DOI: 10.1002/mp.13942
PUBMED: 32418343
PROVIDER: scopus
PMCID: PMC7322982
DOI/URL:
Notes: Article -- Export Date: 1 June 2020 -- Source: Scopus