Motion correction for augmented fluoroscopy - Application to liver embolization Conference Paper


Authors: Ross, J. C.; Subramanian, N.; Solomon, S. B.
Title: Motion correction for augmented fluoroscopy - Application to liver embolization
Conference Title: 2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, ISBI
Abstract: Hepatic embolization is a procedure designed to cut off blood supply to liver tumors, either hepatocellular carcinomas (HCC) or metastases from other parts of the body. While it often serves as a palliative treatment, it can also be indicated as a precursor to liver resection and liver transplants. The procedure itself is conducted under fluoroscopic X-ray guidance. Contrast agent is administered to opacify the vasculature and to indicate the arterial branches that feed the treatment target. These supply routes are then blocked by embolic agents, cutting off the tumor's blood supply. While methods exist to enhance fluoroscopic images and reduce the dependency on contrast agent, they are typically confounded by patient respiratory motion and are hence not effective for abdominal interventions. This paper presents an appearance based tracking algorithm that quickly and accurately compensates for the liver's bulkmotion due to respiration, thereby enabling the application of fluoroscopic augmentations (i.e. image overlays) for hepatic embolization procedures. To quantify the accuracy of our algorithm, we manually identified vascular and artificial landmarks in fluoroscopy sequences acquired from three patients during free breathing. The average postmotion compensation landmark misalignment was 1.9 mm, with the maximum landmark misalignment not exceeding 5.5 mm. ©2008 IEEE.
Keywords: blood; liver; tumors; embolization; fluorescent screens; boolean functions; technical presentations; motion compensation; blood supply
Journal Title International Symposium on Biomedical Imaging. Proceedings
Conference Dates: 2008 May 14-17
Conference Location: Paris, France
ISBN: 1945-7928
Publisher: IEEE  
Location: Paris
Date Published: 2008-01-01
Start Page: 1553
End Page: 1556
Language: English
DOI: 10.1109/ISBI.2008.4541306
PROVIDER: scopus
DOI/URL:
Notes: --- - "2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, Proceedings, ISBI" - "IEEE Int. Symp. Biomed. Imaging: Nano Macro, Proc., ISBI" - "Conference code: 73366" - "Cited By (since 1996): 1" - "Export Date: 17 November 2011" - "Art. No.: 4541306" - "Sponsors: Institute of Electrical and Electronic Engineers; Engineering in Medicine and Biology Society; Signal Processing Society" - 14 May 2008 through 17 May 2008 - "Source: Scopus"
Altmetric
Citation Impact
BMJ Impact Analytics
MSK Authors
  1. Stephen Solomon
    424 Solomon