Utility of diffusion-weighted imaging to decrease unnecessary biopsies prompted by breast MRI: A trial of the ECOG-ACRIN Cancer Research Group (A6702) Journal Article


Authors: Rahbar, H.; Zhang, Z.; Chenevert, T. L.; Romanoff, J.; Kitsch, A. E.; Hanna, L. G.; Harvey, S. M.; Moy, L.; DeMartini, W. B.; Dogan, B.; Yang, W. T.; Wang, L. C.; Joe, B. N.; Oh, K. Y.; Neal, C. H.; McDonald, E. S.; Schnall, M. D.; Lehman, C. D.; Comstock, C. E.; Partridge, S. C.
Article Title: Utility of diffusion-weighted imaging to decrease unnecessary biopsies prompted by breast MRI: A trial of the ECOG-ACRIN Cancer Research Group (A6702)
Abstract: PURPOSE: Conventional breast MRI is highly sensitive for cancer detection but prompts some false positives. We performed a prospective, multicenter study to determine whether apparent diffusion coefficients (ADCs) from diffusion-weighted imaging (DWI) can decrease MRI false positives.Experimental Design: A total of 107 women with MRI-detected BI-RADS 3, 4, or 5 lesions were enrolled from March 2014 to April 2015. ADCs were measured both centrally and at participating sites. ROC analysis was employed to assess diagnostic performance of centrally measured ADCs and identify optimal ADC thresholds to reduce unnecessary biopsies. Lesion reference standard was based on either definitive biopsy result or at least 337 days of follow-up after the initial MRI procedure. RESULTS: Of 107 women enrolled, 67 patients (median age 49, range 24-75 years) with 81 lesions with confirmed reference standard (28 malignant, 53 benign) and evaluable DWI were analyzed. Sixty-seven of 81 lesions were BI-RADS 4 (n = 63) or 5 (n = 4) and recommended for biopsy. Malignancies exhibited lower mean in centrally measured ADCs (mm2/s) than benign lesions [1.21 × 10-3 vs.1.47 × 10-3; P < 0.0001; area under ROC curve = 0.75; 95% confidence interval (CI) 0.65-0.84]. In centralized analysis, application of an ADC threshold (1.53 × 10-3 mm2/s) lowered the biopsy rate by 20.9% (14/67; 95% CI, 11.2%-31.2%) without affecting sensitivity. Application of a more conservative threshold (1.68 × 10-3 mm2/s) to site-measured ADCs reduced the biopsy rate by 26.2% (16/61) but missed three cancers. CONCLUSIONS: DWI can reclassify a substantial fraction of suspicious breast MRI findings as benign and thereby decrease unnecessary biopsies. ADC thresholds identified in this trial should be validated in future phase III studies. ©2019 American Association for Cancer Research.
Journal Title: Clinical Cancer Research
Volume: 25
Issue: 6
ISSN: 1078-0432
Publisher: American Association for Cancer Research  
Date Published: 2019-03-15
Start Page: 1756
End Page: 1765
Language: English
DOI: 10.1158/1078-0432.Ccr-18-2967
PUBMED: 30647080
PROVIDER: scopus
PMCID: PMC6420847
DOI/URL:
Notes: Source: Scopus
Altmetric
Citation Impact
MSK Authors