Conformal radiation treatment of prostate cancer using inversely-planned intensity-modulated photon beams produced with dynamic multileaf collimation Journal Article


Authors: Ling, C. C.; Burman, C.; Chui, C. S.; Kutcher, G. J.; Leibel, S. A.; LoSasso, T.; Mohan, R.; Bortfeld, T.; Reinstein, L.; Spirou, S.; Wang, X. H.; Wu, Q.; Zelefsky, M.; Fuks, Z.
Article Title: Conformal radiation treatment of prostate cancer using inversely-planned intensity-modulated photon beams produced with dynamic multileaf collimation
Abstract: Purpose: To implement radiotherapy with intensity-modulated beams, based on the inverse method of treatment design and using a multileaf collimation system operating in the dynamic mode. Methods and Materials: An algorithm, based on the inverse technique, has been integrated into the radiotherapy treatment-planning computer system in our Center. This method of computer- assisted treatment design was used to derive intensity-modulated beams to optimize the boost portion of the treatment plan for a patient with a Tic cancer of the prostate. A dose of 72 Gy (in 40 fractions) was given with a six-field plan, and an additional 9 Gy (in five fractions) with six intensity-modulated beams. The intensity-modulated fields were delivered using dynamic multileaf collimation, that is, individual leaves were in motion during radiation delivery, with the treatment machine operating in the clinical mode. Exhaustive quality assurance measurement and monitoring were carried out to ensure safe and accurate implementation. Results: Dose distribution and dose-volume histogram of the 'inverse method' boost plan and of the composite (72 Gy primary + 9 Gy boost) plan were judged clinically acceptable. Compared to a manually designed boost plan, the inverse treatment design gave improved conformality and increased dose homogeneity in the planning target volume. Film and ion chamber dosimetry, performed prior to the first treatment, indicated that each of the six intensity-modulated fields was accurately produced. Thermoluminescent dosimeter (TLD) measurements performed on the patient confirmed that the intended dose was delivered in the treatment. In addition, computer-aided treatment-monitoring programs assured that the multileaf collimator (MLC) position file was executed to the specified precision. In terms of the overall radiation treatment process, there will likely be labor savings in the planning and the treatment phases. Conclusions: We have placed into clinical use an integrated system of conformal radiation treatment that incorporated the inverse method of treatment design and the use of dynamic multileaf collimation to deliver intensity-modulated beams. The system can provide better treatment design, which can be implemented reliably and safely. We are hopeful that improved treatment efficacy will result.
Keywords: adult; case report; quality control; prostate cancer; algorithm; collimator; computer assisted radiotherapy; radiation dose distribution; radiation field; thermoluminescence dosimetry; human; male; priority journal; article; intensity-modulated beams; inverse technique; multilead collimation
Journal Title: International Journal of Radiation Oncology, Biology, Physics
Volume: 35
Issue: 4
ISSN: 0360-3016
Publisher: Elsevier Inc.  
Date Published: 1996-07-01
Start Page: 721
End Page: 730
Language: English
DOI: 10.1016/0360-3016(96)00174-5
PUBMED: 8690638
PROVIDER: scopus
DOI/URL:
Notes: Article -- Export Date: 22 November 2017 -- Source: Scopus
Altmetric
Citation Impact
BMJ Impact Analytics
MSK Authors
  1. Chandra M Burman
    154 Burman
  2. Zvi Fuks
    427 Fuks
  3. Michael J Zelefsky
    754 Zelefsky
  4. Xiaohong Wang
    18 Wang
  5. Steven A Leibel
    252 Leibel
  6. Gerald J Kutcher
    106 Kutcher
  7. C Clifton Ling
    331 Ling
  8. Thomas J LoSasso
    99 LoSasso
  9. Chen Chui
    144 Chui
  10. Spiridon Spirou
    34 Spirou
  11. Radhe   Mohan
    97 Mohan