Lying-on position of total skin electron therapy Journal Article


Authors: Wu, J. M.; Leung, S. W.; Wang, C. J.; Chui, C. S.
Article Title: Lying-on position of total skin electron therapy
Abstract: Purpose: A technique for whole-body electron therapy with the patient in a lying position has been developed. This technique allows Total Skin Electron Therapy (TSET) for those patients who were previously unable to be treated in a conventional standing position. Methods and Materials: This study was carried out on a Varian 2100C linear accelerator with a 6 MeV high dose rate electron beam. The collimator was open to a width of 36 × 36 era. There were two main procedures, with six dual-field techniques: 1) two static AP/PA vertical dual fields (VDF): the patient laid on the floor transversely under the collimator when the gantry was in a vertical position. A 0.6 cm acrylic board was placed 15 cm away from the patient, then the gantry was rotated 25° clockwise and counterclockwise to treat the patient in the supine and prone positions, respectively. 2) Four oblique junction fields (OJF): the patient laid on the floor in a prone and supine position parallel to the wave guide at (227 - body thickness × tan 60°) cm away from the vertical axis of the gantry, then the gantry was rotated 60° toward the patient A 0.6 cm acrylic board was placed 15 cm away from the patient perpendicular to the beam. The patient was move along the need central axis. It allowed the patient's body to be within the 160 cm effective treatment profile. When the patient's body axis move 5° toward the lateral side of the field central axis, we could obtain a better dose distribution in the vertex of the scalp and the soles of the feet. The angle of the VDF was measured by chamber detectors to obtain the effective treatment profile. Likewise, the optimal profile for the OJF was determined by the same procedures. The Rando phantom was used to measure the superficial dose of the body. Results: The dimension of effective treatment profile for the VDF was 188 × 72 cm at 87% dose level. For the OJF, we had to move the patient along the field central axis to obtain the effective treatment profile in a 180 × 85 cm dimension at a 87% dose level The vertex and sole dose measured in this setup was in the range of 89-88%. Conclusions: The empirical data showed that the lying-on position for TSET was technically feasible. The dose distribution in the body surface was also compatible with the Stanford standing technique. The nonambulatory skin malignancy patient can be treated in a comfortable and reproducible position. © 1997 Elsevier Science Inc.
Keywords: dose response; treatment planning; radiation dose; reproducibility; skin neoplasms; skin cancer; feasibility studies; data analysis; collimator; patient positioning; electrons; whole-body irradiation; electron beam; supine position; humans; human; priority journal; article; recumbency; lying-on position; skin malignancy; total skin electron therapy (tset)
Journal Title: International Journal of Radiation Oncology, Biology, Physics
Volume: 39
Issue: 2
ISSN: 0360-3016
Publisher: Elsevier Inc.  
Date Published: 1997-09-01
Start Page: 521
End Page: 528
Language: English
PUBMED: 9308958
PROVIDER: scopus
DOI: 10.1016/S0360-3016(97)00141-7
DOI/URL:
Notes: Article -- Export Date: 17 March 2017 -- Source: Scopus
Altmetric
Citation Impact
BMJ Impact Analytics
MSK Authors
  1. Chen Chui
    144 Chui