Prospective evaluation of biodegradable polymeric sealant for intraoperative air leaks Journal Article


Authors: Park, B. J.; Snider, J. M.; Bates, N. R.; Cassivi, S. D.; Jett, G. K.; Sonett, J. R.; Toloza, E. M.
Article Title: Prospective evaluation of biodegradable polymeric sealant for intraoperative air leaks
Abstract: Background: A biodegradable polymeric sealant has been previously shown to reduce postoperative air leaks after open pulmonary resection. The aim of this study was to evaluate safety and efficacy during minimally invasive pulmonary resection. Methods: In a multicenter prospective single-arm trial, 112 patients with a median age of 69years (range 34-87 years) were treated with sealant for at least one intraoperative air leak after standard methods of repair (sutures, staples or cautery) following minimally invasive pulmonary resection (Video-Assisted Thoracic Surgery (VATS) or Robotic-Assisted). Patients were followed in hospital and 1month after surgery for procedure-related and device-related complications and presence of air leak. Results: Forty patients had VATS and 72 patients had Robotic-Assisted procedures with the majority (80/112, 71%) undergoing anatomic resection (61 lobectomy, 13 segmentectomy, 6 bilobectomy). There were no device-related adverse events. The overall morbidity rate was 41% (46/112), with major complications occurring in 16.1% (18/112). In-hospital mortality and 30-day mortality were 1.9% (2/103). The majority of intraoperative air leaks (107/133, 81%) were sealed after sealant application, and an additional 16% (21/133) were considered reduced. Forty-nine percent of patients (55/112) were free of air leak throughout the entire postoperative study period. Median chest tube duration was 2days (range 1 - 46days), and median length of hospitalization was 3days (range 1 - 20days). Conclusions: This study demonstrated that use of a biodegradable polymer for closure of intraoperative air leaks as an adjunct to standard methods is safe and effective following minimally invasive pulmonary resection. Trial registration: ClinicalTrials.gov: NCT01867658. Registered 3 May 2013. © 2017 The Author(s).
Keywords: lung cancer; lung surgery; robotic surgery; video-assisted thoracic surgery; intraoperative air leak; pleural air leak sealant; postoperative air leak
Journal Title: Journal of Cardiothoracic Surgery
Volume: 11
Issue: 1
ISSN: 1749-8090
Publisher: Biomed Central Ltd  
Date Published: 2016-12-12
Start Page: 168
Language: English
DOI: 10.1186/s13019-016-0563-3
PROVIDER: scopus
PMCID: PMC5154021
PUBMED: 27955681
DOI/URL:
Notes: Article -- Export Date: 3 January 2017 -- Source: Scopus
Altmetric
Citation Impact
BMJ Impact Analytics
MSK Authors
  1. Bernard J Park
    263 Park